Blog Archive

Pet Cremation Incinerator System (30–50 kg/h) HICLOVER TS50PET

HICLOVER TS50PET Pet Cremation Incinerator System (30–50 kg/h) Product Overview The HICLOVER TS50PET Pet Cremation Incinerator is a purpose-designed, industrial-grade cremation system engineered for the dignified and environmentally responsible disposal of animal remains. Designed around proven dual-chamber incineration principles and enhanced flue-gas treatment stages, …

incinerator

l) Ease of Use and maintenance i) The unit should be simple to learn to use, operate, and maintain. ii) The unit should have abbreviated operating instructions included on or with the unit (e.g., on a laminated card attached to the unit). …
Gasified incineration for burning medical wastes

Gasified incineration for burning medical wastes

Gasified incineration for burning medical wastes.   Fuel type: Natural Gas Burning Capability: –   30-50 kg/time –   Daily 3-6 times   Incinerator size: max 2000x1200x3200 mm Burning room volume: –   Gasification room max 0.7 m3, –   Secondary burning room max 0.5 m3, …
medical waste incinerator for sale

medical waste incinerator for sale

Waste type: health care waste Waste density: 125 to 350Kg/M3 Waste calorific value: 4000KCAL/kg Moisture content: 10 – 25% Estimated ash residue: 5 – 10% Nominal capacity: 50kg/hr batch load Secondary chamber: 2 seconds@850?C Environmental: NEMA ACT (EMCA) 1999, Waste Management regulations, …
Laying Garbage to waste

Laying Garbage to waste

The world’s largest incinerator will ensure that Beijing’s household garbage is not only disposed of in an eco-friendly manner, but also produces electricity for the energy-hungry city. The world’s largest waste incinerator will start running at full speed next month after one …

incinerators 300 kg per hour

Manual autoclave with vertical loading; gravity displacement type with possibility for Vacuum.   Capacity:      Up to 12 kg/h   Chamber size:      >150 liters   Material:       Stainless steel   Temperature:       134 °C   Further information:   Minimum autoclave chamber size shall be 150 …
incinerators

incinerate biohazard waste

an incinerator which is capable of burning between 3 to 5 tonnes per day of mixed waste products, plastics, rubber, flammable putrescible waste, medical waste, rubber tyres, paper and cardboard, textiles, green timber waste etc. As some of the waste products will …

medical incinerator china

The Volume of the combustion chamber at least: 1.200 L   The Dimension of the door for loading in cm at least: 70×70.   The Incinerator Plant is output wastes incineration from Different petrochemical units. In this project we want to incinerate …

pequeño incinerador de desechos médicos

Somos fabricante y vendedor de equipos médicos de incineración. Nuestra filosofía es mejorar continuamente nuestra tecnología en línea con las crecientes necesidades del medio ambiente y nuestros clientes. Todos nuestros incineradores se construyen con los más altos estándares de durabilidad, facilidad de …

msw incinerator manufacturers

standard type, 11m long ,self supporting Capacity-220kgs/hr refuse-hospital waste average moisture-15-20% on fist time DIMENSIONS height: 2710mm length: 2840mm Width; 2450mm loading door opening: 610mm x 610mm Grate/Heath Area: 2.0(square meters) Primary chamber volume: 2.4(cubid  meters) secondary chamber volume :2,72(cubid meters0 total …

Small Scale Medical Waste Incinerators

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions …

30 kg per hour-incinerator

Secondary combustion chamber shall be either the rotary- or stationary-hearth (or kiln) type incinerator designed to   oxidize (or burn) the organic vapors and gases. Burner and combustion air controls shall be fully automatic Diesel incinerator of 25Kg / h     …
hospital incinerator manufacturer

hospital incinerator manufacturer

Incinerator to have double combustion chamber and control amount of dioxin and other gasses emitted without being harmful. Estimated dimensions, to manufacturers standard, but to be compact as possible. capacity: approximately 60kg per day, voltage: 220V and diesel fired. CSH  Hospital, (Calabar, …

china medical waste incinerator

Incinerate: medical waste and general waste Capacity to burn waste: 400 — 500 kg/hr Fuel: Diesel Fuel Consumption: 10 litres/hr maximum Incineration temperature: 950 – 1300 °c Casing: thick (min 5 mm) Stainless steel casing and fully insulated to withstand sea humidity …
incinerators

pet incinerator deisel

and forced air exhaust stacks (or chimneys).   The charging system shall consist of, as a minimum, a hopper for top feeding and mechanically operated hydraulic   charging ram or augur. To prevent warpage or excessive thermal expansion, a charger cooling system …

Doubel Combustion Chamber High Temperature Incinerator

All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World. Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.

incinerator burners

Fully automatic sequential control provided by internal PLC system providing control of: Secondary chamber pre-heat Burn cycle (variable) Cool down cycle Fuel Options Diesel, LPG, Natural or Bio Gas. Typical Fuel Consumption Diesel: 8 / 10 litres per hour Liquid Propane Gas: …
dispose  Medical waste IV

dispose Medical waste IV

the incinerator can be used to dispose  Medical waste IV, used needles, used syringes, scalpels, used dressing material ,personal protective equipments like gown, gloves etc. amputated body parts, excreta from patients and other laboratory waste.incineration units that can handle a mix of …

china animal cremation

The panel shall comprise of a compartment for the connection of power and control cables. Passage for power cables and control cables shall be made by the bottom part of the switchboard.         The drawer shall be locked in …

medcial incinerator manufacturer

The successful Bidder shall inform CEB in writing at least three (3) weeks prior to the carrying out of factory tests so as to enable sending of one CEB Engineer for witnessing  of  the  factory  tests.    A  ‘Factory  Acceptance  Test ’  schedule  …
incinerator for medical waste

incinerator for medical waste

MINIMUM REQUIREMENTS FOR ENGINE OF INCINERATION CAPACITY OF INCINERATION 30KG / H 1. GENERAL SPECIFICATIONS: The incinerator for medical waste must be designated for the destruction of all types of waste produced by the Center for Health (waste type hospital, clinic, medical …

pet incinerator for sale

1.    Capacity of destruction in weight: 60 Kg/h. 2.    It should be able to operate not less than 10 hours/day 3.    This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc… 4.    Design Specification …
INCINERATEUR COMBUSTION DESTRUCTION OF MEDICAL WASTE PYROLYTIC AND LABORATORY,incinerator medical waste manufacturer

ecologically friendly incinerator

50 bed hospital and would like to have your recommendation for incinerator that can effectively handle the load of 50 bed hospital.Incinerator for burnable garbage (paper & organic) medium capacity (100/150 lts). Bio Medical Waste Incinerators, Capacity: 50kgs per hour Medical Waste Incinerator  Model  …

animal incinerator prices

This incinerator with “PYROLYTIC” combustion must have: 1.A combustion chamber of waste: oPerfectly tight door for the manual loading of waste. The loading should be Manual, Batch Load oA burner of lighting which the use is limited to the ignition of waste. …

medi burn 30 contraband incinerator

air retention for at least 2 seconds at a temperature of less than 850C, the combustion In order to achieve the proper effect. ? must be a two-chamber incinerators, primary and secondary Fuel stoves ? The waste products to reduce the initial …
animal incinerators for sale

animal incinerators for sale

SMART ASH INCINERATORS FOR THE DISPOSAL OF HAZARDOUS WASTE ?    Quantity: 20 units ?    The Incinerator works with a 55 gallon open ended steel drum ?    The unit operates without fuel and used only 120v or 220v electricity for the blowers ?   …
incinerator for medical waste

Dual-chamber controlled air incinerator

Materials of construction: The incinerator shall not have any asbestos, asbestos-containing substances, mercury thermometers, and mercury switches. Refractory materials shall be able to meet relevant standards under ISO TC33 and CEN/TC                                                                               187. Types of incinerator design acceptable: Dual-chamber controlled air incinerator or …
INCINERATEUR COMBUSTION DESTRUCTION OF MEDICAL WASTE PYROLYTIC AND LABORATORY,incinerator medical waste manufacturer

WASTE INCINERATOR

  –          150 KG/HR –          Compliant with EU rules, Directive 2000/76/EC –          Fuel type: Diesel –          Easy management and maintenance –          Temperatures: 850 deg C for municipal waste 1000 deg C for medical waste 1100 deg C for dangerous waste containing halogenated …

small scale medical incinerator

The burners shall comply with the requirements of BS 799 or DIN Standards. Each shall be the packed type and incorporate automatic stop/start programmed timer control, flame failure equipment and ignition failure equipment to close off the fuel supply in the event …
Four representative garbage incinerator

Four representative garbage incinerator

Waste incineration technology sprouted in the late 1800s. Since the 20th century, with the development of greatly improved and incineration of municipal waste production, waste incineration has become in many countries to develop waste treatment technology. Garbage incinerator waste incineration is the …
Getting a grip on our garbage

Getting a grip on our garbage

Nobody likes to be thought of as a garbage factory but — like it or not — that is what cities have always been and will continue to be, despite our sense of sophisticated entitlement. While only the most narrow-minded would dismiss …
Medical Waste Incinerator 50 to 60 Kg/hr

Medical Waste Incinerator 50 to 60 Kg/hr

Medical Waste Incinerator, 50 to 60 Kg/hr Item Quantity 5 No. Support Health Sector Support Project Point of Installation (Hospitals) Moi Voi, Makindu, Maragua, Eldama Ravine and Isiolo District Hospitals 1. General Description Supply, delivery, installation and commissioning of a medical waste …

china incinerators

An innovative system for medical facilities. It has been designed to eliminate hospital waste (including infectious and pathological waste) efficiently, and with a minimum of expense. Existing personnel can be instructed on the use of this product. The operator opens the primary …

Medical Waste treatment unit

Medical Waste treatment unit The medical waste treatment unit shall be environmentally-friendly, and have a capacity of about 200-300kg per batch , to enable treatment of medical waste generated in a 160-bed hospital The equipment should be self-steam generating if steam is …

Sudan Medical waste Treatment Scheme

•    A burn rate of 25 – 30kg/hr. •    Consists of two chambers to ensure significant reduction of emissions and be capable of temperatures in the range of 800-1000˚c. •    Incinerator must be of a low maintenance design, be diesel fuelled and …

animal waste incinerator

secondary chamber 1000 degree   chimney standard   shredder separately   Autoclave or microwaves separately   temperature monitor attached outside of machine   operating Fuel and electric During the start and end incineration operations at the waste incineration plant the temperature shall …
Containerized Incinerator

Containerized Incinerator

Now you can move your incinerator by truck to anywhere! Containerized waste incinerator is our latest design for market. This incinerator is build in ISO container before leave factory. After customer received container, install the chimney and connect with electric power and …
chinese incinerator manufacturers

chinese incinerator manufacturers

In a simple design with a metal steel drum electric. including: A cage for receipt of biomedical waste; A combustion chamber with fireplace with a filter to retain ashes; A cover; An air supply; A turbine  allowing the supply of the air. …
Chamber Double Incinerator

Chamber Double Incinerator

Chamber Double Incinerator: Burning Rate      10 kg per hour (for two incinerators) Burning Rate     20 kg per hour (for three incinerators) Loading   Method   Manual No of Burners   Single for 10 kg/hour and Double for 20 kg per hour Fuel                    Diesel and Natural …

Biomedical Waste Incinerator, 10-15 KG 

Biomedical Waste Incinerator, 10-15 kg Manufacturer: Brand: Type / Model: Country of Origin: Description of Function The Biomedical Waste Incinerator is used for Incineration of each type of Biomedical Waste. The Disposal of such Biomedical waste is a very important as it is a dangerous wastes for human life, and It is only possible with a perfect incinerator. Operational Requirements It shall be operated by manual and automated mode. The combustion efficiency (CE) shall be at least 99.00%. The combustion efficiency is computed as follows: C.E.= __%CO2______ x 100 %CO2 + %CO Emission Standards: Lower emission rates are preferred. Parameters                   Concentration in mg/Nm3 (12% CO2 correction Max total dust              30mg/m3 Max Sulphur Dioxide      200mg/m3 Max Nitrogen dioxide    400mg/m3 Max Carbon                     100mg/m3 Monoxide Minimum stack height shall be 30 metres above ground. Volatile organic compounds in ash shall not be more than 0.01%. System Configuration Biomedical Waste Incinerator, complete unit. Technical Specifications Incinerator: It shall be Electrical or Diesel Fired Incinerator or Controlled Air & pyrolytic. Type of Waste: Biomedical Waste It shall have burning capacity 10-15 kg/hr. Fuel: Diesel Burner: Monoblock fully automatic burners. Temperature: Primary Chamber 800 ± 50 oC, Secondary Chamber 1050 ± 50 oC. Type of Waste: Biomedical waste with moisture content up to 85%. Destruction Efficiency: 99%. It shall have separate digital display of temperature for both chambers. It shall have provision for measuring primary & secondary chamber temperatures using external thermo coupler. Secondary chamber gas residence time shall be minimum 1 second at 1050 oC. Primary Chamber: Type: Static Solid Hearth …
WASTE CATALOGUE AND HAZARDOUS WASTE LIST

WASTE CATALOGUE AND HAZARDOUS WASTE LIST

1 Incinerator 30 =KG  burn/h and it must have a Scrubber. 2 Incinerator must have Electrical Plastic Shredder for cutting of glass bottle,surange of Medicine. 3 Incinerator must have Electrical Auto Clave or Microwave for Dis Infection  separately with incinerator. 4 Incinerator …
Incinerator Questions

Incinerator Questions

Technological University of Panama: an environmental research about the municipal waste in Panama city. I found some incinerators from Clover Incinerator and I think they are perfect for my research but I have a question and it is if the incinerator can …