Blog Archive

Medical waste incineration system

Medical waste incineration system of 300 kg/hr burn rate with dual fuel (gas and diesel) type, daily 8-16 hrs operation and a stack height of 15 meter.Primary combustion i.    The primary combustion chamber shall be accepted as the primary combustion zone; ii.   …

Tips to Choose Perfect Party Shoes

Magni dolores eos qui ratione voluptatem sequi nesciunt. Neque porro quisquam est, qui dolorem ipsum quia dolor sit amet, consectetur, adipisci velit, sed quia non numquam eius modi tempora incidunt ut labore et dolore magnam aliquam quaerat voluptatem. Ut enim ad minima …
small capacity incinerators

small capacity incinerators

1    Basic Plant Design    An approved plant must have four distinct sections that demonstrate three principles of Turbulence, Residence Time and Temperature are inbuilt in the plant design .The regulated sections may include but not limited to: Overall plant layout. Feed chamber/ …
INDUSTRIAL INCINERATORS

INDUSTRIAL INCINERATORS

Large incinerators – INDUSTRIAL INCINERATORS – specs below. 2.) Size requirement for the incinerators is 750 — 850 kg capacity 3.) The bum rate should be 80 LL 100 kg/ hour. 4) The primary chamber shouId have an operating temperature of 900 …
incinerator for medical waste

GENERAL SPECIFICATIONS FOR INCINERATORS

Primary and secondary burners: Separate electrically spark-ignited primary burners and secondary burners with automatic control shall be used to achieve the specified temperature requirements in the primary and secondary chambers. The flames  of the primary and secondary burners shall not impinge on …

petite échelle incinérateur de déchets médicaux

Nous sommes fabricant et vendeur de matériel médical incinérateur. Notre philosophie est d’améliorer continuellement notre technologie en ligne avec les besoins croissants de l’environnement et nos clients. Tous nos incinérateurs sont construits pour les plus hauts standards de durabilité, de convivialité et …

animal incinerators china

Incinerate: medical waste and general waste Capacity to burn waste: 400-500kg/hr Fuel: Diesel Fuel Consumption: 10 liters/hr maximum Incineration temperature: 950-1300 degrees centigrade Casing: thick (min 5mm) stainless steel casing and fully insulated to withstand sea humidity Voltage 220/240v or 380/415V Frequency …

medical small incinerator

Dimensions: World standard: 0.83m(I) x 1.0m(w) x 1.4m(h) Burning efficiency: >98% china double chamber incinerator Features: ?     Waste type and burn rate: Designed specifically for use by poultry farmers, game-keepers and for pet cremation. The incinerator will burn up to 50 kg …

Incinerator Introduction

  Principle of the Incinerator equipment is incineration/combustion/burn. Generally, the function is waste treatment for Solid waste, Liquid waste, Gas waste, etc.   The main body is one combustion chamber (at least), Refractory line or firebrick, Insulation materials and the outer plate. …

Two combustion chambers type incinerator

Load Capacity minimum:  1500 kg Burner fuel type:  Diesel Burner fuel rate max.:   20-25 Liter diesel/ per hour Burners minimum: 3 Burning rate minimum: 200-300kg/per hour Furnace bar area minimum: 2 м3 Fuel tank capacity minimum: 300L Main chamber burning temperature min. …

For incineration, general and pathological incinerators

Main unit Application    For incineration, general and pathological Capacity      50 – 60 kg/h burn rate Type    Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit Operating time                   Minimum 8 hours daily …

incinerators for sale from china

Incinerators used will be limited to daylight hours of operation. This includes shutdown, cleaning and maintenance.   Waste streams shall not be mixed during the incineration process and the ash collection chamber will be cleaned when a different waste stream is to …

500kg/day burn capacity incinerator

in acinerator with 300 kg/ hour by double filter wet and dry.Pet Dead Body Incinerator upto 80 kg ,gas operated is prefered. animal waste incinerator with capacity about 40Kgs. We will use this product to burn the animal corpses in normal way (not …
Hot Sale Small Scale Waste Incinerators 30 and 50 kgs per hour capacity

Incenerator System

  Incenerator Supply, installation and testing of medical waste incinerator with a capacity of 75 kilograms / hour, operated by LPG and including all accessories with chimney in accordance with the technical specifications and public health regulations Item 2 Incinerators room for …
Duke of Kent officially opens Billingham incinerator

Duke of Kent officially opens Billingham incinerator

His Royal Highness, the Duke of Kent yesterday (8 October) officially opened SITA consortium’s energy-from-waste (EfW) facility at Billingham, Teesside. Built as part of the SITA UK, Lend Lease Infrastructure (EMEA) Ltd, and I-Environment Investments Ltd (ITOCHU Corporation), the facility forms part …

Shoes For Exercise

Et harum quidem rerum facilis est et expedita distinctio. Nam libero tempore, cum soluta nobis est eligendi optio cumque nihil impedit.recusandae. Vero eos et accusamus et iusto odio dignissimos ducimus qui blanditiis praesentium voluptatum deleniti atque corrupti quos dolores et quas molestias …

pet crematory

The temperature is over the minimum and under the maximum required temperature (e.g 1150?C) of the thermal reactor (partial load).   When switching off, only the solenoid valve for the fuel supply closes, the burner fan stays on to cool and protect …
INCINERATOR DIESEL DRIVEN

INCINERATOR DIESEL DRIVEN

INCINERATOR, DIESEL DRIVEN waste type : HEALTH CARE WASTE Waste calorific value : 4000KCAL/KG Moisture Content : 10-25% Nominal Capacity : 50Kg/Hour batch load Secondary Chamber : 2 Seconds @ 850degrees C The primary combustion chamber must ensure minimum exit temperature is …

medical waste incinerators china

Ensure flame contact with all gases is achieved. –yes Ensure residence time is not less than two (2) seconds. –yes Ensure the gas temperature as measured against the inside wall in the secondary chamber & not in the flame zone, is not …

pet incinerators

  The panel and parts hereof shall have the following characteristics:         Finish   All metal parts shall receive a treatment taking the prevailing environment conditions into account.         The top paint colour shall be the …

infectious waste pyrolysis machine china

(b) Fluctuation: (i)  Mains fluctuation is a common problem, the performance should be affected by this problem a tolerance of ±15% or more in both the nominal voltage should be allowed. (ii) Mains Cut-off (black out) is a common problem. Where necessary, …
hospital incinerator manufacturers

hospital incinerator manufacturers

The Incinerator Plant is output wastes incineration from Different petrochemical units. In this project we want to incinerate all output wastes from petrochemical units and also produced high pressure steam from incinerator plant heat generated. At first output waste from petrochemical collects …
china animal incinerator, buy a pet incinerator,

Smart Ash Incinerators

Smart Ash Incinerators 1. Size requirement for the incinerators is that the unit works with a 55 gallon open ended steel drum. 2. The unit should operate wit. no fuel and use only 120V or 220V electricity for the blowers. 3. The …
waste incinerator manufacturer china

waste incinerator manufacturer china

waste incinerator manufacturer china, Waste chamber Chamber capacity 300 kg Chamber volume .54m3 Chamber size (outside) Width: 91cm, Height: 86cm Length: 152cm Door opening 66 x 76 cm Height to door 84 cm Height to top of stack 5.4 m Suggested slab …
WASTE INCINERATOR

WASTE INCINERATOR

INCINERATOR (WASTE INCINERATOR) Designed to burn disposables that can and should be destroyed on-site. Theses wastes include infectious and contaminated “red bag.” Surgical dressings, plastic test devices and other wastes Fast, complete, efficient waste disposal Dual chamber combustion, Chambers insulated and lined …
incinerator for medical waste

smart ash incinerator

(G) Technical Specifications of Spore tester Features and Specifications : It is an auto reader for Bacillus Stearothermophilus to test the spore discharge after treatment (sterilization) of the waste. should be a very Accurate, reliable and easy-to-use units for reading rapid readout …

animal cremation

Technical Specifications of External SHREDDER Controls: Pre-programmed PLC controlled Password activated and reversal history indication Motor starter with overload protection Automatic instantaneous stop on hard object in shredder bed Automatic heavy cutting load reversal and re-try , up to three times Control …

install a diesel fired incinerator

incinerate mainly pharmaceuticals ( all types of dosage forms … syrups, tablets, injectables ) medical consummabables, and also biological fluids … Capacity around 10 kg/ hour. install a diesel fired incinerator that can accommodate a batch load of up to 100 kg …
animal waste incinerator manufacturer

animal waste incinerator manufacturer

Technical specification for burning machine,animal waste incinerator manufacturer 1.Two systems are required to be installed in the south of the Kingdom of Saudi Arabia. The two systems will be used by custom authority to burn different kinds of drugs. All need equipment …

Women’s Flower Headband